Time Domain:
Signal Delay
Risetime, thru into 50 Ω
Frequency Domain:
Insertion loss
Equivalent Circuit Parameters:
Inductance:
S to GND capacitance:
Transmission line:
1000 V
<15m Ω
> 109 Ω
2 amps
2 ps
30 ps
(test system
risetime)
0.5 dB to 25 GHz
< 1 dB to 40 GHz
0.094 nH
0.023 pF
Z0=55 Ω
T1 = 2 (typ) ps
750 V
<25m Ω
>109 Ω
1 amp
2 ps
30 ps
(test system
risetime)
< 0.5 dB to 25 GHz
< 1 dB to 40 GHz
0.094 nH
0.023 pF
Z0=55 Ω
T1 = 2 (typ) ps
Frequency Domain
The lumped element
model for the elastomer
itself consist of a Pisection
consisting of a
120 pH inductor and two
0.016 pF shunt capacitors.
Lumped element
equivalent circuit
Reliability
Temperature Cycling (contact resistance after
315 cycles, -20ºC to +100ºC:
Gold-plated contacts
Corrosive Atmosphere (contact resistance after 1000 hrs.
with temperature-humidity cycling): Gold-plated
contacts
Shock and Vibration per EIA-540, Test Procedure FP2
and FP3:
<1% change
<5% change
pass
<1% change
<5% change
pass
Please take a little time to review our products or if you like call for assistance at any time day or night seven days a week. 1-800-540-4210 International +1-775-833-4395
Email: engineering@connect2it.com